Exporting from Nhava Sheva·Mundra·Hazira·Chennai

Amines 47 products

Aliphatic, alkanolamine, ethyleneamine, heterocyclic, aromatic and fatty amines — 47 products across seven groups, each shipped with a batch-specific COA and current SDS.

Dye Intermediates 30 products

Dye and pigment intermediates for reactive, disperse, acid and azo chemistries — 30 products across three families, each shipped with a full COA and SDS.

Agrofarm Intermediates 46 products

High-purity aromatic intermediates for crop protection and fine-chemical synthesis — 46 products across four families, each shipped with a full COA and SDS.

Pharmaceutical Intermediates 18 products

API intermediates, acylating reagents, tablet and capsule excipients and vitamins — 18 products across four families, each shipped with a batch-specific COA and current SDS.

Petro & Oilfield 73 products

Base petrochemicals, polymers, synthetic elastomers, industrial solvents and refinery feedstocks — 73 products across nine groups, each shipped with a batch-specific COA and current SDS.

Can’t find a product? Send us the name or CAS number and we’ll check availability.

Talk to the technical team
Aromatic · Phenol & Acetone Feedstock

Cumene CAS 98-82-8

Chelora Chemicals supplies phenol-grade cumene to phenol, acetone and alpha-methylstyrene producers worldwide. Because cumene forms peroxides, every consignment leaves with a batch-specific COA covering purity, peroxide value and sulphur, the current SDS and full dangerous-goods documentation.

Also known as: Isopropylbenzene · 2-Phenylpropane · Cumol · 1-Methylethylbenzene

Worldwide supplyExport shipments to Asia, Europe, the Middle East and the Americas
Phenol grade testedPurity, peroxide value and sulphur reported on every COA
Bulk and drum packingDrums, ISO tanks, road tankers and bulk parcels
Full traceabilityCOA, SDS and dangerous-goods documentation on every lot

Request a quotation

Price, lead time and a sample COA for Cumene, usually within one working day. We ship worldwide.

Request a Quote Email the Desk

Documentation

  • Batch-specific COA (GC purity, peroxide value, sulphur)
  • Safety Data Sheet (SDS)
  • Transport and dangerous-goods documents
  • Third-party inspection on request
  • Certificate of origin
Overview

What is Cumene?

Cumene is a C9 aromatic carrying an isopropyl group, formula C₉H₁₂. It is a clear flammable liquid boiling at 152 °C with a sharp aromatic odour.

Its importance is entirely due to one reaction sequence. Oxidation of the tertiary carbon gives cumene hydroperoxide, and acid cleavage of that peroxide produces phenol and acetone together in a fixed molar ratio.

Over 95% of world cumene goes through that route, which is why phenol and acetone markets are permanently linked: you cannot make one without the other, whatever the relative demand.

Why Cumene specifically

  • A tertiary benzylic carbon. The isopropyl group oxidises selectively to a stable hydroperoxide, which is the whole basis of the phenol process.
  • Co-production economics. Each tonne of phenol brings about 0.6 tonnes of acetone, tying the two markets together.
  • Made from benzene and propylene. Both feedstocks are widely available, which keeps the route dominant.
  • Peroxide forming. The same reactivity means cumene accumulates peroxides in storage and must be managed accordingly.
Production

How Cumene is Manufactured

Cumene is made by alkylating benzene with propylene, almost always over zeolite catalysts in modern plants.

  • Benzene and propylene feed. Dry, low-sulphur benzene is alkylated with chemical or polymer grade propylene.
  • Zeolite alkylation. Liquid-phase alkylation over beta or MCM-22 zeolite gives high selectivity to mono-isopropylbenzene.
  • Transalkylation. Di-isopropylbenzene by-product is transalkylated with benzene to recover more cumene.
  • Benzene recycle. Excess benzene is distilled overhead and returned, so feed purity affects the whole loop.
  • Fractionation. Cumene is separated from benzene and from heavier alkylates to reach 99.9%.
  • Legacy SPA route. Older plants used solid phosphoric acid, which gives lower selectivity and more heavy by-products.
What this means commercially: cumene is almost always made inside phenol complexes, so merchant volume is limited and priced off benzene and propylene plus conversion. Buyers outside the phenol chain should expect contract supply rather than a liquid spot market.
Specification

Typical Commercial Specification

Figures below are representative of commercial phenol-grade cumene. Tell us whether the material goes to oxidation or to a solvent use and we will advise on the limits you should specify.

ParameterTypical Value
AppearanceClear colourless liquid, free of suspended matter
Cumene purity99.9% min by weight
BenzeneTo grade, typically 50 ppm max
n-PropylbenzeneTo grade, typically 300 ppm max
Ethylbenzene and butylbenzenesTo grade, typically 300 ppm max
Total sulphurTo grade, typically 1 ppm max
Peroxide value (as cumene hydroperoxide)To grade, typically 5 ppm max
WaterTo grade, typically 100 ppm max
Colour (Pt-Co)10 max
ChloridesTo grade, typically 1 ppm max
n-Propylbenzene is the specification that catches people out. It oxidises much more slowly than cumene and accumulates in the oxidation loop, so phenol plants specify it tightly even though it looks like an innocuous isomer.
Properties

Physical & Chemical Properties

PropertyValue
Chemical formulaC₉H₁₂ (C₆H₅CH(CH₃)₂)
Molecular weight120.19 g/mol
AppearanceClear colourless liquid, sharp aromatic odour
Boiling point152.4 °C
Melting point−96 °C
Flash pointAbout 36 °C (closed cup)
Density0.862 g/cm³ at 20 °C
Vapour pressureAbout 0.4 kPa at 20 °C
Vapour density (relative to air)4.1, heavier than air
Flammable limits in airAbout 0.9 to 6.5% by volume
Autoignition temperatureAbout 420 °C
Solubility in waterPractically insoluble (about 0.05 g/L)
IncompatibilitiesOxidisers, acids, peroxide formers; forms hydroperoxide on air exposure

Behaviour in the process

Cumene is a stable solvent in ordinary use, but its oxidation chemistry needs respect:

  • Peroxide formation. Air exposure slowly produces cumene hydroperoxide, which is both the industrial intermediate and a storage hazard.
  • Selective oxidation. The tertiary benzylic hydrogen is abstracted preferentially, giving a clean hydroperoxide in the industrial process.
  • Acid-sensitive peroxide. Cumene hydroperoxide cleaves violently with acid, which is exploited industrially and must be avoided in storage.
  • Static accumulation. Low conductivity means charge builds during splash filling; bonding and earthing are essential.
Comparison

Cumene and Alternative Phenol Routes

Cumene is bought for the phenol process, and the alternatives are different phenol technologies rather than different chemicals.

MaterialOrigin / typeWhen it is the right choice
Phenol-grade cumene99.9%+, low n-propylbenzenePhenol and acetone manufacture by the cumene process
Technical-grade cumene99%+Solvent, thinner and specialty chemical use
PhenolThe product, CAS 108-95-2Bought directly where no oxidation and cleavage unit exists
Toluene (via benzoic acid)CAS 108-88-3An alternative phenol route operated on a small scale
CyclohexylbenzeneAlternative hydroperoxide routeProduces phenol with cyclohexanone instead of acetone

Stated plainly: the cumene process dominates phenol production because both products have markets. The alternative routes exist mainly for producers who do not want the acetone co-product.

Industries

Industries We Supply Cumene To

Cumene goes mostly to one reaction, with a modest solvent and specialty market beside it.

Phenol and acetonePhenol complex operators running oxidation and cleavage
Polycarbonate chainBisphenol-A producers downstream of phenol and acetone
Epoxy resinsBPA epoxy producers downstream
Nylon chainCaprolactam producers using phenol routes
Coatings and solventsThinner and specialty solvent formulators
Specialty chemicalsAlpha-methylstyrene, acetophenone and intermediate producers
Applications

Where Cumene is Used

Phenol and acetone manufacture accounts for nearly all cumene consumption worldwide.

Phenol Via cumene hydroperoxide and acid cleavage, the dominant use.
Acetone The fixed co-product of the same cleavage reaction.
Bisphenol-A Downstream of phenol and acetone for polycarbonate and epoxy.
Alpha-methylstyrene By-product of the cumene process, used in heat-resistant ABS.
Acetophenone Oxidation by-product used in fragrance and pharmaceutical chemistry.
Solvent Limited use as a high-boiling aromatic solvent and thinner.

In the cumene process

Cumene is oxidised with air at about 100 °C to cumene hydroperoxide at 20 to 30% concentration, then concentrated and cleaved with sulphuric acid to phenol and acetone. The cleavage is strongly exothermic and is one of the most carefully controlled reactions in the industry, which is why feed purity, particularly n-propylbenzene and sulphur, is specified tightly.

As a solvent

Cumene's 152 °C boiling point and strong solvency make it useful in thinners and specialty coatings, but peroxide formation on air exposure limits its shelf life compared with toluene or xylene. Peroxide testing on aged stock is a sensible precaution.

Need a specific grade, purity and packing format?

Tell us the grade, the n-propylbenzene and sulphur limits your oxidation unit needs, the packing format you can receive and the annual quantity. We will come back with a price, a lead time, a sample COA and the full documentation set.

Quality

Quality Control & Testing

Every lot is released against a batch-specific Certificate of Analysis, with peroxide value and n-propylbenzene reported alongside purity because both matter directly to the phenol process.

  • Cumene purity — by gas chromatography, the primary grade measure.
  • n-Propylbenzene — reported because it accumulates in the oxidation loop.
  • Benzene and other alkylbenzenes — measured as feed quality and recycle indicators.
  • Peroxide value — tested because peroxides form on air exposure and affect oxidation control.
  • Total sulphur and chlorides — reported in ppm for catalyst and corrosion reasons.
  • Colour and water content — confirming freedom from contamination and moisture pick-up.
Pre-shipment samples: for oxidation feed we send an analysis from the actual lot before the consignment ships, so your lab can confirm the n-propylbenzene and peroxide figures before the material reaches the oxidiser.
Troubleshooting

Common Process Problems & Likely Causes

When cumene causes trouble, it is usually n-propylbenzene build-up, peroxides, sulphur or water. This table is the shortcut our technical desk works through before anyone opens a complaint file.

SymptomLikely causeWhat to check
Inerts accumulating in the oxidation loopn-Propylbenzene in the feed oxidising slowlyn-Propylbenzene figure on the COA and purge rate
Hydroperoxide selectivity fallingSulphur, metals or phenolic contaminationSulphur result and transfer equipment cleanliness
Peroxide value high on receiptAir exposure during storage or transportPeroxide result, blanketing and lot age
Acetone to phenol ratio offFeed impurities producing alternative cleavage productsPurity and alkylbenzene profile
Corrosion in the cleavage sectionChlorides or water in the feedChloride and water figures on the COA
Colour in the delivered materialOxidation products or rust contaminationPt-Co colour and tank condition
Before you reject a batch: send us the lot number along with your purity, n-propylbenzene and peroxide data. With cumene, oxidation complaints usually resolve into one of those figures, and identifying the cause is more productive than changing supplier.
Logistics

Packaging, Storage & Shipping

  • Standard packing. 200 L drums, ISO tank containers, road tankers and bulk parcels.
  • Nitrogen blanketing. Standard, because cumene forms hydroperoxide on air exposure.
  • Storage. Cool, shaded, well-ventilated, earthed and bunded flammable-liquid storage away from ignition sources.
  • Peroxide management. Test peroxide value on aged stock; never distil cumene to dryness, as concentrated peroxide is explosive.
  • Material compatibility. Carbon steel and stainless steel are standard. Avoid contact with acids, which cleave any hydroperoxide present violently.
  • Segregation. Keep apart from oxidisers, acids and peroxide initiators.
  • Shelf life. Typically 12 months in blanketed storage. Peroxide value is the practical check.
  • Transport classification. UN 1918, isopropylbenzene, Class 3 flammable liquid, packing group III.
Practical tip: never evaporate or distil cumene to dryness in the laboratory or the plant. Any hydroperoxide present concentrates in the residue, and concentrated cumene hydroperoxide decomposes explosively.
Safety

Hazards & Safe Handling

Cumene is a flammable liquid with aspiration and irritant hazards that also forms hydroperoxides on air exposure. Peroxide management is the handling issue that distinguishes it from other aromatic solvents.

Flammable liquid Aspiration hazard Peroxide former Skin irritant Heavier-than-air vapour
  • Flammability. Flash point about 36 °C with a flammable range of roughly 0.9 to 6.5%. Control ignition sources and bond transfer equipment.
  • Peroxide hazard. Cumene hydroperoxide forms on air exposure and decomposes violently with acid or on concentration. Blanket, test and never evaporate to dryness.
  • Aspiration hazard. Swallowing and aspirating liquid can cause chemical pneumonitis. Never induce vomiting.
  • Health classification. Skin and respiratory irritant with narcotic effects at high vapour concentration; listed by IARC as possibly carcinogenic to humans.
  • Occupational exposure. Typical limits sit around 25 to 50 ppm as an 8-hour average; confirm the limit in your jurisdiction.
  • Heavy vapour. Vapour pools at low points. Ventilate and monitor at low level.
  • Environment. Harmful to aquatic life; prevent entry to drains and watercourses.
Compliance

Regulatory & Compliance Notes

Cumene is regulated as a flammable liquid with additional attention to its peroxide-forming behaviour. The notes below are orientation rather than legal advice.

  • GHS classification. Flammable liquid Category 3, aspiration hazard Category 1, skin and respiratory irritant, and hazardous to the aquatic environment.
  • Peroxide-forming chemical status. Many laboratory and plant safety codes classify cumene as a peroxide former with a defined maximum storage period after opening.
  • REACH and inventories. Registered under EU REACH and listed on the major chemical inventories.
  • Dangerous goods transport. UN 1918, Class 3, PG III. ADR, IMDG, IATA and DOT rules apply to packaging, labelling and routing.
  • Quality agreements. Phenol producers commonly expect documented n-propylbenzene, sulphur and peroxide limits with change control.
Documentation is part of the product: for material shipped across borders, the SDS, the transport declaration and the batch analysis are what make the consignment legally movable and safely usable. We supply them with every consignment rather than on request.
Global Supply

We Supply Cumene Worldwide

Chelora Chemicals is a supplier and export partner, not a single-plant trader. We ship Cumene from India and from partner sources to customers across Asia, Europe, the Middle East, Africa, and North and South America, handling the export documentation, transport paperwork and freight so the material arrives ready to use.

Asia PacificChina, Korea, Japan, Taiwan, Vietnam, Indonesia, Thailand
EuropeGermany, Italy, Spain, Turkey, Netherlands, Poland, UK
Middle EastUAE, Saudi Arabia, Oman, Qatar, Iran
AmericasUnited States, Mexico, Brazil, Argentina, Colombia
AfricaEgypt, Morocco, South Africa, Kenya, Nigeria
Domestic IndiaGujarat, Maharashtra, Tamil Nadu, Himachal, Sikkim and all major industrial belts
  • Incoterms. EXW, FOB, CIF, CFR and DAP quoted to suit your purchasing terms and freight arrangements.
  • Ports. Regular shipments through Nhava Sheva (JNPT) and Mundra, with other ports arranged where routing and cargo rules allow.
  • Documentation. Commercial invoice, packing list, certificate of origin, COA, SDS and the transport declaration issued as a complete set.
  • Flexible volumes. From a single ISO tank up to repeat bulk shipments on a supply contract.
  • Supply continuity. Because we are independent of any one producer, a plant turnaround or a shipping disruption at one source does not have to become your stock-out.
Supply

Buying Cumene from Chelora

We are an independent sourcing and supply partner. For cumene that means settling three things at enquiry: the purity and n-propylbenzene ceiling, the peroxide value and blanketing on arrival, and the logistics into your tankage.

  • Documentation on every lot. Batch-specific COA (GC purity, peroxide value, sulphur), plus SDS and the full transport paperwork.
  • Analysis before commitment. Representative analysis shared ahead of a commercial order so your lab can qualify the material.
  • Quantities. From a single ISO tank through to full bulk shipments on contract supply.
  • Grade matching. Phenol grade or technical grade, with the n-propylbenzene, sulphur and peroxide limits your unit requires.
  • Inspection. Independent third-party inspection available at loading when the contract requires it.
  • Related products. Benzene, Phenol, Acetone and other feedstocks alongside Cumene from one supplier.

How ordering works

  • Send the enquiry. Product, grade or purity, quantity, destination port and the Incoterm you buy on. If you have a spec sheet, attach it — it saves a round trip.
  • We quote. Price, lead time, packing format and a sample COA, normally within one working day.
  • Qualify the supply. For first orders or critical applications, we share the analysis and handling documentation so your technical and safety teams can sign off before you commit.
  • Confirm the order. Proforma invoice issued; payment terms agreed against the volume and the relationship.
  • Allocation and QC. Material allocated and released against a batch-specific COA, with an independent inspection where the contract calls for it.
  • Ship and document. Filled, labelled and loaded with the full export document set, and tracked through to arrival.
FAQ

Cumene — Common Questions

The questions our technical desk is asked most often about Cumene. If yours isn't here, call or email and you will reach someone who knows the chemistry.

What is the CAS number of cumene?

The CAS number for cumene is 98-82-8, and its EC number is 202-704-5. Its molecular formula is C₉H₁₂ with a molecular weight of 120.19 g/mol, and it is classified under HS code 2902.70.

What is cumene used for?

Almost entirely for phenol and acetone manufacture through the cumene hydroperoxide process. Smaller volumes go to alpha-methylstyrene, acetophenone and solvent applications.

Do you supply cumene worldwide?

Yes. Chelora Chemicals supplies and exports cumene worldwide — across Asia Pacific, Europe, the Middle East, Africa and the Americas, as well as throughout India. Every consignment carries the COA, the SDS and the dangerous-goods documentation.

Why are phenol and acetone always produced together?

Because the cumene process cleaves cumene hydroperoxide into both products in a fixed molar ratio. Roughly 0.6 tonnes of acetone accompanies every tonne of phenol, whatever the relative demand for the two.

How is cumene manufactured?

By alkylating benzene with propylene over a zeolite catalyst in the liquid phase, with transalkylation of di-isopropylbenzene to improve yield. Older plants used solid phosphoric acid catalysis.

Why is n-propylbenzene specified so tightly?

Because it oxidises far more slowly than cumene and accumulates in the oxidation loop as an inert, forcing a higher purge rate and reducing plant efficiency. It is a process constraint rather than a purity cosmetic.

Is cumene hazardous?

It is a flammable liquid with a flash point around 36 °C, an aspiration hazard and an irritant. It also forms hydroperoxides on air exposure, which is the hazard that distinguishes it from other aromatic solvents.

What are the UN number and transport class?

UN 1918, isopropylbenzene, Class 3 flammable liquid, packing group III. ADR, IMDG, IATA and DOT rules apply to the packaging, labelling and routing.

How should cumene be stored?

Under nitrogen in cool, shaded, earthed and bunded flammable-liquid storage away from acids and oxidisers, with peroxide value tested on aged stock.

Why should cumene never be distilled to dryness?

Because any hydroperoxide present concentrates in the residue, and concentrated cumene hydroperoxide decomposes explosively. This applies in the laboratory as much as in the plant.

What packing sizes and order quantities are available?

200 L drums, ISO tank containers, road tankers and bulk parcels. Orders run from a single ISO tank up to repeat bulk cargoes on contract supply.

What is the typical shelf life?

Around 12 months in sealed, nitrogen-blanketed storage, limited by peroxide formation. Peroxide value is the practical check on older stock.

Ready to source Cumene?

Send us your specification, grade and annual volume. You will get a price, a realistic lead time and a sample COA from someone who understands what the material has to do in your process — delivered anywhere in the world.